Type: | Internal Resistance Tester |
---|---|
Test Region: | All |
Item: | Battery Resistance Tester |
Capacity and Cycle Testing: | 5V 5mA 5V3a 5V6a, 10V6a 10V 20A etc |
Battery Internal Resistance Testing: | Bk-300, Bts-100 |
Finished Battery Testing: | Gn-301 |
Customization: |
---|
Suppliers with verified business licenses
BTS-5V3A Battery Testing System | |||||||||||||||||||
Model: | BTS- | 5 | V | 3000 | mA | Material Code: | CT-3008 | -5V3000mA | - | - | S4 | ||||||||
Description | Product Specification | ||||||||||||||||||
AC Input | AC 110V±10% 50Hz /220V | ||||||||||||||||||
Power | 212658 | mW | |||||||||||||||||
Resolution | AD: 16bit; DA: 12bit | ||||||||||||||||||
Input Impedance | ≥1MΩ | ||||||||||||||||||
Voltage |
Measuring Range | Charge: 10mV~5V |
Discharge: 10mV~5V |
||||||||||||||||
Discharge Min Voltage | 80mV | ||||||||||||||||||
Accuracy | ± 0.1% of FS | ||||||||||||||||||
Stability | ± 0.1% of FS | ||||||||||||||||||
Current |
Each channel output Range | Charge: 6mA~3000mADischarge: 6mA~3000mA | |||||||||||||||||
Accuracy | ± 0.1% of FS | ||||||||||||||||||
Stability | ± 0.1% of FS | ||||||||||||||||||
Power |
Output Power Per Channel | 15000mW | |||||||||||||||||
Stability | ± 0.2% of FS | ||||||||||||||||||
Time | Rise Time | 20ms | |||||||||||||||||
Step Time | ≤ (365*24) hour/stepTime Format 00:00:00 (h:min:s) | ||||||||||||||||||
Data Acquisition |
Intervals |
Time interval Δt:(1s~60000s) | |||||||||||||||||
Voltage interval ΔU: (10mV~5V) | |||||||||||||||||||
Current interval ΔI: (6mA~3000mA) | |||||||||||||||||||
Frequency | 1Hz | ||||||||||||||||||
Charge |
Modeof Operation | CCC, CVC, CC & CVC | |||||||||||||||||
End Conditions | Voltage, Current, Test Time, Capacity | ||||||||||||||||||
Discharge |
Modeof Operation | CCD, CPD | |||||||||||||||||
End Conditions | Voltage, Current, Test Time, Capacity | ||||||||||||||||||
Cycle |
Cycles | 1~65535times | |||||||||||||||||
Steps | 63 | ||||||||||||||||||
Nested Function | Max three levels of loops | ||||||||||||||||||
Protective Function |
Software |
Power-off data protection | |||||||||||||||||
Off-line Operating | |||||||||||||||||||
User-defined safety(upper and lower)tolerance of current, voltage and delay time | |||||||||||||||||||
Channel Features | Independent pairs of closed loop for constant current source and constant voltage source | ||||||||||||||||||
Channels | Independent control | ||||||||||||||||||
Detection and Sampling | 4-wire Connecting | ||||||||||||||||||
Noise Density | <85dB | ||||||||||||||||||
Communication Means | RS232(note: PC should equip the serial port card) | ||||||||||||||||||
Export Formats | EXCEL, TXT | ||||||||||||||||||
Communication Interface | Serial port | ||||||||||||||||||
Number of Channels Per Cabinet | 8 | ||||||||||||||||||
Operating Environment | |||||||||||||||||||
Description | Product Specification | ||||||||||||||||||
Operating Temperature | 0ºC~40ºC | ||||||||||||||||||
Storage Temperature | -10ºC~50ºC | ||||||||||||||||||
Operating Humidity | ≤70% RH | ||||||||||||||||||
Storage Humidity | ≤80% RH | ||||||||||||||||||
Description | Product Specification | ||||||||||||||||||
Holder | Universal Holder | ||||||||||||||||||
Holder Picture |
|
Suppliers with verified business licenses