Customization: | Available |
---|---|
Type: | Notebook Battery Tester |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
BTS-5V100mA four range tester specification | |||||
Equipment material encoding: | CT-4008Q-5V100mA-124 | ||||
Indicator project | Specification | ||||
Input power | AC 220V ±10% / 50Hz | ||||
Enter a powerful power | 40 W | ||||
Resolution | AD:24bit;DA:16bit | ||||
input resistance | ≥1GΩ | ||||
Voltage | Constant voltage voltage range control | 10mV~5V | |||
Mini discharge voltage | -5V | ||||
Precision | ± 0.01% of FS | ||||
stability | ± 0.02% of FS | ||||
Current | Output range per channel | Range 1:0.2μA~0.1mA;Range 2:0.1mA~1mA; Range 3:1mA~10mA ;Range 4:10mA~100mA |
|||
Precision | ± 0.01% of FS | ||||
Constant voltage cutoff current | Range 1:0.1μA; Range 2:1μA;Range 3:1μA; Range 4:0.1mA | ||||
stability | ± 0.02% of FS | ||||
Power | Single channel maximum output power | 0.5 W | |||
stability | ± 0.1% of FS | ||||
Time | Current response time(10%FS~90%FS) | ≤1.5ms | |||
Step time range | ≤(365*24)hour/step | Time format support 00:00:00:00(h,min,s,ms) | |||
Data record | Data recording conditions | Mini time interval:10ms | |||
Mini voltage interval:5mV | |||||
Mini current interval:range 1:0.1μA;range 2 :1μA range 3:10μA; range 4 :0.1mA | |||||
Recording frequency | 100Hz | ||||
Charge | Charge mode | Constant current charging, constant voltage charging, constant current constant pressure charge, constant power charging | |||
Cut off condition | Voltage, current, relative time, capacity, - △ V | ||||
Discharge | Discharge mode | Constant current discharge, constant voltage discharge, constant current constant pressure discharge, constant power discharge, constant resistance | |||
Cut off condition | Voltage, current, relative time, capacity | ||||
Pulse mode | Charge | Constant current mode, constant power mode | |||
Discharge | Constant current mode, constant power mode | ||||
Mini pulse width | 500ms | ||||
Pulse number | Single pulse joint supports 32 different pulses | ||||
Charge and discharge continuous switch | One pulse process can achieve continuous switching from charging to discharge | ||||
Cut off condition | Voltage, relative time | ||||
DCIR test | Support custom pointing points for DCIR calculations | ||||
Cycle | Circular test range | 1~65535 times | |||
Single cycle step | 254 | ||||
Cycle nested | With nested cycle function, the maximum support 3 layers of nested | ||||
Protection | Power-down data protection | ||||
Offline test function | |||||
Security protection conditions can be set, the setting parameters include: the upper limit, the lower current limit, the current limit, the upper capacity limit, delay time | |||||
IP protection level | Protective level IP20 | ||||
Channel characteristics | Constant current source and constant pressure source adopt double closed loop structure | ||||
Channel control mode | Independent constant flow source and constant voltage source adopt double closed loop structure control | ||||
Voltage current detection sampling | Four-wire connection | ||||
Noise | <45dB | ||||
Database | Centralize management test data with MySQL database | ||||
Upset machine communication method | TCP / IP protocol | ||||
Server operating system | Windows 7/Windows 10 | ||||
Data output | EXCEL2003,2010,TXT | ||||
Server disk configuration | 500GB | ||||
Communication Interface | Network port | ||||
Leakage current | 0.005μA | ||||
Total channels | 8 | ||||
Equipment work environment requirements | |||||
Indicator project | Specification | ||||
Range of working temperature | 0ºC~40ºC(In the range of 25 ± 10 ºC, ensure measurement accuracy: accuracy drift 0.005% of FS / ºC) | ||||
Storage temperature range | -10ºC~50ºC | ||||
Work environment relative humidity range | ≤70% RH(No water, gas condense) | ||||
Storage environment relative humidity range | ≤80% RH(No water, gas condense) | ||||
Clamp specifications and size | |||||
Indicator project | Specification | ||||
Clamp type | Polymer clamp | ||||
Clamp images | |||||
Crocodile clamp | Polymer clamp | PCB coin cell clamp | |||
The picture is just for reference , pls refer to the actual product | |||||
Each unit chassis size(W*D*H)(mm) | 1U(19"),443*310*43 | ||||
The tester's photo | |||||
The picture is just for reference , pls refer to the actual product |